Elysia alpha compressor Bedienungsanleitung Seite 27

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 39
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 26
27
REFERENCE Attack & Auto Fast Attack
Attack
Here a burst signal (a sine tone that is boosted by 12 dB for a period of 100 ms) is used to demon-
strate the eectiveness of the attack controller. The dierent curves show how fast this level jump
is reduced by 4 dB. On fast settings the reduction takes only a few milliseconds, on longer settings
the reduction does not only take longer, but it is also smaller. Therefore the amount of gain reduc-
tion is always higher on fast attack settings than on longer settings.
Auto Fast Attack
Utilizing a burst signal again, this diagram shows a comparison between a normal attack time of
50 ms (dark curve) and the later added Auto Fast function (light curve). This reveals how fast this
circuit reacts: Even the rst waves of the burst are already reduced by 2.3 dB. The whole gain re-
duction now happens much faster, too. Note: This function starts working at -3 dB; on lower gain
reduction values the changes in dynamics are too small to trigger it accurately.
Seitenansicht 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 38 39

Kommentare zu diesen Handbüchern

Keine Kommentare